Home / Services / Structured Cabling & Fiber

Structured Cabling & Fiber

The physical backbone your network runs on.

Overview

Certified copper and fiber cabling that gives your network a clean, documented foundation to grow on.

Every network, security system, and connected device in your office depends on the cable plant behind the walls. MyIThub designs and installs standards-compliant structured cabling systems — Cat6, Cat6A, single-mode and multi-mode fiber — built to ANSI/TIA specifications and certified end to end.

Fiber is the part of the plant you buy once and live with for twenty years — which is why MyIThub engineers it to a calculated loss budget before anyone touches a splicer. We design single-mode (OS2) for campus, riser, and long-haul runs, and laser-optimized multimode (OM3/OM4/OM5) where short-reach economics win, with MPO/MTP trunking for high-density data center and IDF aggregation.

What's included

Copper Cabling Systems

Cat6 and Cat6A horizontal cabling, patch panels, and workstation drops — installed to spec and certified with test reports.

Fiber Optic Backbone

Single-mode and multi-mode fiber design, fusion splicing, termination, and OTDR testing for inter-building and riser backbones.

Cable Plant Certification

Every drop certified with calibrated test equipment — full documentation and labeled as-builts delivered at closeout.

Moves, Adds & Changes

Ongoing MAC support to keep the cable plant clean, documented, and audit-ready as your office evolves.

Low-Voltage Pathway Planning

Coordination of sleeves, conduit, J-hooks, ladder rack, and routing so installations remain serviceable.

MPO/MTP High Density

Pre-terminated trunk and cassette systems for data center rows and IDF aggregation — polarity engineered, not guessed.

Standards and specifications

The design basis we work from. Every project is scoped to your environment.

Copper mediaCategory 6 and 6A (U/UTP, F/UTP); Cat8 for short-reach 25/40G server links
Fiber mediaOS2 single-mode; OM4/OM5 multimode; MPO/MTP trunks for 40/100/400G
Link design90 m permanent link inside a 100 m channel per ANSI/TIA-568.2-D
PoE engineeringBundle sizing and cable class for IEEE 802.3bt Type 4 (90 W) loads
Copper certification100% of links certified, full-parameter test reports delivered in native format
Fiber testingTier 1 OLTS loss testing on every strand; Tier 2 OTDR on backbones
Grounding & bondingTMGB/TGB bonding backbone per ANSI/TIA-607-D
AdministrationOutlet, panel, and pathway labeling with as-built drawings per TIA-606-C
ConnectorsLC, SC, and MPO/MTP connectivity · APC where reflectance matters
SplicingFusion splicing ≤0.05 dB typical · mechanical only where specified
Strand counts12- to 288-strand counts, engineered spare capacity

ANSI/TIA-568.2-DANSI/TIA-568.3-DTIA-569-ETIA-606-CTIA-607-DBICSI TDMMIEEE 802.3bt

What to expect

  • Standards-compliant installs (ANSI/TIA-568, BICSI best practices)
  • Certified test results on 100% of installed links
  • Clean, labeled, documented infrastructure that reduces future service costs
  • A documented loss budget for every link
  • Spare strands planned into the backbone for growth

Questions about structured cabling & fiber

Do you label and test every cable?

Yes. Labeling and testing are important parts of a professional cabling project because they reduce future troubleshooting time.

Do you handle both data and camera cabling?

Yes. We can cable for workstations, wireless, cameras, access control devices, phones, and other low-voltage systems.

When is fiber better than copper?

Fiber is often better for longer distances, higher bandwidth, building backbones, campus connections, and areas with interference concerns.

Can fiber support cameras?

Yes. Fiber is commonly used for cameras in parking lots, remote buildings, large facilities, and industrial environments.